Electronic Design for a Bleeding Detector to be Used in Intraoperative Radiotherapy Applications

2021

An electronic design for a bleeding detector used with mobile linac during intraoperative radiotherapy (IORT) is presented. It consists on a readout circuit based on a De Sauty Bridge and a wireless power supply using a supercapacitor. The goal is the measurement of the height of fluid present in the applicator in order to avoid a misadministration dose during the irradiation process. A minimum measurement height of 5 mm is required by clinic to be confident with the selected radiation dose. The measurement circuit uses a capacitive sensor which detects variations lower than 0.1 pF. The readout circuit converts dynamic capacitance variation from the bleeding detector into an analog voltage …

FluidsMaterials scienceIntraoperative radiotherapybleeding detectorCapacitive sensingDetectorDe Sauty bridgecapacitive sensorLinearityCapacitive sensorsDetectorsRepeatabilityApplicatorsmobile linacsCapacitanceSignalLinear particle acceleratorBridge circuitswireless supplyElectrical and Electronic EngineeringHemorrhagingInstrumentationVoltageBiomedical engineering
researchProduct

Detector for monitoring potential bleeding during electron intraoperative radiotherapy

2018

Purpose: The aim of this work is to develop a bleeding detector integrated into the acrylic circular applicators for specific mobile linacs. Thus, a bleeding detector has been developed based on a capacitive sensor to be used with plastic applicators, as in the case of LIAC HWL from Sordina IORT Technologies SpA. According to the clinical impact, we have selected 0.5 cm as the minimum depth of fluid that should be detected. Methods: An experiment was developed using water-simulating blood. Two setups were considered: non-beveled applicators with 7 cm and 10 cm diameter. Measurements were done for applicators 0 degrees and 45 degrees tilted, both with respect to the horizontal surface, in or…

Intraoperative radiotherapyMaterials scienceCapacitive sensingBiophysicsPhase (waves)General Physics and AstronomyElectronsHemorrhageRadiation030218 nuclear medicine & medical imagingIntraoperative Period03 medical and health sciences0302 clinical medicineOpticsRadiology Nuclear Medicine and imagingIrradiationRadiation InjuriesRadiotherapybusiness.industryBleedingContinuous monitoringDetectorLinearityGeneral MedicineBevel030220 oncology & carcinogenesisCapacitive sensorParticle AcceleratorsbusinessPhysica Medica
researchProduct

Polytetrafluoroethylene Films in Rigid Polyurethane Foams' Dielectric Permittivity Measurements with a One-Side Access Capacitive Sensor.

2021

As a non-metallic composite material, widely applied in industry, rigid polyurethane (PUR) foams require knowledge of their dielectric properties. In experimental determination of PUR foams’ dielectric properties protection of one-side capacitive sensor’s active area from adverse effects caused by the PUR foams’ test objects has to be ensured. In the given study, the impact of polytetrafluoroethylene (PTFE) films, thickness 0.20 mm and 0.04 mm, in covering or simulated coating the active area of one-side access capacitive sensor’ electrodes on the experimentally determined true dielectric permittivity spectra of rigid PUR foams is estimated. Penetration depth of the low frequency excitation…

dielectric permittivityMaterials sciencePolymers and PlasticsCapacitive sensing02 engineering and technologyDielectricengineering.materialLow frequency01 natural sciencesArticlelcsh:QD241-441chemistry.chemical_compoundlcsh:Organic chemistryCoatingone-side access0103 physical sciencesComposite materialPenetration depthPolyurethane010302 applied physicsPolytetrafluoroethylenepolyurethane foamscapacitive sensorGeneral Chemistryprotectionpolyurethane foams; dielectric permittivity; capacitive sensor; one-side access; adverse effects; protection; PTFE films021001 nanoscience & nanotechnologychemistryPTFE filmsElectrodeadverse effectsengineering0210 nano-technologyPolymers
researchProduct

Experimental Investigation on Innovative Stress Sensors for Existing Masonry Structures Monitoring

2023

Historical masonry structures often suffer gradual deterioration that in many cases can compromise the safety levels and the operating conditions of the buildings. In this context, Structural Health Monitoring (SHM) is an effective tool for the prediction of the structural behaviour and the state of conservation of buildings. Although many monitoring systems have recently been proposed, there is a lack of practical application of low-cost systems. This paper presents an experimental study based on the use of two innovative stress sensors—capacitive stress sensor and ceramic stress sensor—for the monitoring of existing masonry elements. In order to reproduce the actual conditions of onsite m…

Fluid Flow and Transfer ProcessesmonitoringSettore ICAR/09 - Tecnica Delle CostruzionimasonryProcess Chemistry and Technologycapacitive sensorGeneral Engineeringpiezo-resistive sensorGeneral Materials ScienceSHM; masonry; monitoring; capacitive sensor; piezo-resistive sensorSHMInstrumentationComputer Science ApplicationsApplied Sciences
researchProduct